CSL/XCSL High-temp. reheating furnace
CSL reheating furnace: using temperature 1600-1700℃, classic energy-saving lining, GM heater
XCSL reheating furnace: using temperature 1600-1800℃, all fiber energy saving lining, GM heater. Rapid heating and cooling.
More models please consult:
Implementation standards: GB, metallurgical standards and enterprise standards
Measurement and control method:
P: Industrial PC, can realize group control, database management
Y: Wall type 3100 intelligent controller or T2100 controller, multi meter communication
L: Color LCD touch screen
Electric source: AC380V, single-phase or three-phase. The controller supply for single phase power is wall type 3100 intelligent device.
Measurement and control points: one point, two points, three points or more points measurement and control.When multi points measure, the temperature difference between each point is less than 5℃
Heating rate: meet the relevant test methods or in accordance with the contract agreement
Loading: bottom door lifting, unilateral door or double doors
furnace sizes: L 150~2000 W 150~1500 H 150~1500
主流型号设备选型指导:
Optional parameter
Temperature control: single / double zone temperature control;
Control mode: LCD touch screen /P3100 series intelligent temperature controller /IPC computer
Equipment application description:
Tester according to GB/T3997.1 and GB/T5988, is used for measuring line shrinkage of refractory material, and can also be used for sintering test of material.
Device characterization
The controller and the furnace body are integrated structure
Using B type thermocouple temperature measurement and control
Double gas curtain furnace shell, temperature rise of furnace wall surface is less than room temperature + 45℃ for 1600℃ heat insulation for 1 hours.
Intelligent PID measurement and control, automatic heating, thermal insulation and stop furnace, thermocouple broken , limit current and short circuit protection
4 Related literature
GB/T 5988-2007 Refractory products—Determination of permanent change in dimension on heating